Node Runtime: Ingestion Producer & Trigger Dispatch Consumer
This guide covers how engine/node_runtime.py implements the Node Runtime, the piece that makes a Node instance actually run continuously.
It repeatedly calls the mechanisms between a System Connector and a dispatched Task (TransformationRegistry, IdentityResolver, MesIngestion.ingest(), TriggerQueue.claim() and dispatch_claimed_entry()) in a long-running process. It does so as two composable pieces that are independently testable:
- a Trigger Dispatch consumer loop (sections 1 to 3);
- per-Node-Type ingestion producers and pollers (sections 4 to 6).
1. Trigger Dispatch consumer loop
from engine.activity_log import ActivityLog
from engine.node_runtime import TriggerHandler, TriggerHandlerRegistry, run_trigger_dispatch_loop
from engine.trigger_queue import TriggerQueue
from engine.try_catch import RetryPolicy
queue = TriggerQueue()
activity_log = ActivityLog()
handlers = TriggerHandlerRegistry()
handlers.register(
"order_release",
TriggerHandler(
step=process_order_release, # (payload: dict, entry: TriggerQueueEntry) -> Any
task_type="ingestion-time classification",
retry=RetryPolicy(max_attempts=3),
),
)
run_trigger_dispatch_loop(
queue,
activity_log,
handlers,
node_type="MES",
node_instance_id="mes-line-3",
) # blocks forever - run this as the node process's own main loop
TriggerHandlerRegistry maps trigger_type to TriggerHandler. It is the same keyed-registry dispatch shape that ConnectorRegistry and TransformationRegistry use (engine/registry.py), for the same reason: trigger_type was designed as a column, not a per-type queue, so registering a new one needs no change to the loop itself.
What the loop does
Each pass claims at most one pending row and dispatches it through dispatch_claimed_entry (see trigger-dispatch-queue.md), using its registered handler's step, retry and repair.
- No pending row.
claim()returningNonemakes the loop sleep forclaim_poll_interval(default 0.5 s) rather than busy-polling Postgres. - Scheduled tasks (below) each run on their own independent background thread, not inline in this loop. A slow or blocking scheduled task can therefore never delay claiming and dispatching an already-pending row.
TriggerHandler.step takes two arguments
step receives the claimed row's payload dict (dispatch_claimed_entry's own contract) and the genuine claimed TriggerQueueEntry itself.
- A handler that only needs
payloadcan ignore the second argument (lambda payload, _entry: ...). - One composing an already-built, self-logging Task class that expects a real
TriggerQueueEntryneeds the genuine row, not a fabricated stand-in.CaseTriage.processinengine/case_triage.pyis an example: it readsentry.idandentry.trigger_typedirectly for its Activity Logreference_ids. dispatch_claimed_entryitself is never touched to make this work.run_trigger_dispatch_loopadapts a two-argumentstepinto the one-argument shapedispatch_claimed_entrycalls, closing over the claimed entry it already has in scope (_bind_entry, private).
An unrouted trigger_type
A claimed row with no registered handler is dead-lettered through the normal dispatch path. That path uses a step that always raises PromptCausedFailure, with retry=RetryPolicy(max_attempts=1). It does not crash the loop or leave the row claimed forever. This is the same fail-safe-and-report stance the Conformance Suite established for an unregistered source_type (engine/conformance.py).
2. Crash recovery: reclaim_orphaned_claims
run_trigger_dispatch_loop calls queue.reclaim_orphaned_claims() once at startup, before its first claim(). It resets every row still claimed back to pending.
This is what keeps a crash mid-dispatch from orphaning a row. Exactly one consumer loop runs per node instance, so any row already claimed when a loop starts can only be a previous, crashed run's leftover, never a row a concurrently running claimer legitimately holds. Restart requeues it through claim() and dispatch_claimed_entry() like any other pending row, still bounded by that dispatch's own Try/Catch retry policy.
3. Scheduled checks (and polling producers)
from engine.node_runtime import ScheduledTask
task = ScheduledTask(
name="spc-deviation-check",
interval_seconds=30.0,
run=lambda: deviation_flagging.check_batch(fetch_latest_points()),
)
run_trigger_dispatch_loop(
queue, activity_log, handlers, node_type=..., node_instance_id=..., scheduled_tasks=[task]
)
The "scheduled check" vocabulary (Deviation Flagging's check_batch, for example) and a polling Ingestion Producer's poll cadence are the same primitive: "run this callable every interval_seconds". Both share ScheduledTask rather than each feature inventing its own timer.
Each ScheduledTask runs on its own background thread, started by run_trigger_dispatch_loop itself and joined in its own finally block. It is not called inline from the claim/dispatch loop.
task.run()fires immediately, then again everyinterval_seconds. The wait between firings isstop_event.wait(interval), so a shutdown mid-wait is noticed immediately rather than only once the full interval elapses.- Why a thread. A
ScheduledTask'srunmay do real I/O that can block for longer than a heartbeat, such as a poll against a flaky OPC UA sidecar. Inline execution would stall claiming and dispatching an already-pending row that has nothing to do with that poll. - Isolation. A genuine bug in one task's
runkills only that task's own thread (Python's defaultthreading.excepthook), not the whole dispatch loop.
4. Per-Node-Type Ingestion Producer: MES
from engine.connector import OpcuaConnectorProfile
from engine.node_runtime import MesIngestionProducer
producer = MesIngestionProducer(
OpcuaConnectorProfile(endpoint="opc.tcp://plc.line3:4840", node_id="ns=1;i=5000"),
mes_ingestion, # an already-built engine.mes_ingestion.MesIngestion
source_type="mes-opcua-explicit",
trigger_type="order_release",
)
producer.run() # starts the subscription and returns - events keep arriving after this
How run() behaves
- Subscribing.
run()callsOpcuaConnector.subscribe()(orpubsub_subscribe()if built withpubsub=True) and returns once subscribed. It doesn't loop itself for delivery, since that already happens on the sidecar's background reader thread (engine/opcua_sidecar.py) once subscribed. - Retrying the first subscribe. It does retry its own initial subscribe attempt, up to
INGESTION_STARTUP_RETRY_ATTEMPTStimes (INGESTION_STARTUP_RETRY_DELAY_SECONDSapart) onSidecarError. See the last Pitfalls entry for why this matters. - One ingest per event. Each delivered event turns into exactly one
MesIngestion.ingest()call, with a freshuuid4()trigger_idper event. OPC UA'sdata_changeandpubsub_dataevents carry no sequence number to derive a redelivery-stable id from.
The producer owns its connector
The producer owns its OpcuaConnector. The connector must be built with on_event pointing back at the producer's own handler, so construction order requires the producer to build the connector itself, not accept a pre-built one.
Test injection uses process_factory, the same SidecarProcess-level hook the tests in test_connector_opcua.py use, not sidecar=. See MesIngestionProducer.__init__'s docstring for why.
Other producers
The other producers in engine/node_runtime.py follow the same convention: a run()- or poll_once()-shaped entrypoint per source, reusing ScheduledTask for a poll cadence rather than new machinery.
| Producer | Source | Behavior |
|---|---|---|
MqttIngestionProducer |
MES on a plant MQTT broker (mqtt section) |
A message is already a whole record, so nothing is buffered across messages and no first value is suppressed. The connector's handler only puts the record on a bounded in-memory queue. One worker thread runs ingest() in arrival order and then acknowledges the message. Redelivery is caught by the record's trigger_id. |
DatabaseLogIngestionProducer |
MES on a target's database log (database_log section) |
poll_once() runs one DatabaseLogScan per poll_interval_seconds, reading rows past the stored watermark. A row the Trigger Dispatch Queue or the dead-letter table already holds is not offered to ingest() again. A run of max_consecutive_rejections dead-lettered rows stops the scan for the life of the process (one Activity Log entry, the watermark left where it was). A failing poll writes one poll failed: entry when the failure first appears or its message changes, and one poll recovered: when a later poll works. poll_interval_seconds is at least 1. |
ErpIngestionProducer |
ERP, ScheduledTask-shaped over REST polling (poll_interval_seconds in engine/erp_config.py) |
An unchanged poll result is deduped. The last changed poll is published as one immutable LastPoll (raw record plus the material_id that ErpIngestion.ingest resolved for it). |
ScheduleIngestionProducer |
Production Scheduling | The same shape as the ERP producer. A changed record with the same schedule_id is a Schedule Revision that ProductionSchedulingIngestion.ingest reconciles. |
OpcuaMaterialConsumptionPoller |
MES's material_consumption poll |
Reports each new material_id string observed on one OPC UA node, which node_main.py binds to a GenealogyLinkTask.run call. |
Shared helpers and constants
poll_or_logwraps a scheduled poll so any exception is logged and retried on the next tick.observed_only_handler()is aTriggerHandlerthat records an observation without further work (task typetrigger-dispatch: observation recorded).- Constants:
DEFAULT_CLAIM_POLL_INTERVAL0.5 s,SCHEDULED_TASK_SHUTDOWN_JOIN_TIMEOUT5.0 s,INGESTION_STARTUP_RETRY_ATTEMPTS5 andINGESTION_STARTUP_RETRY_DELAY_SECONDS3.0 s.
5. Scalar-value poller feeding a threshold check: OpcuaScalarDeviationPoller
from engine.connector import OpcuaConnector, OpcuaConnectorProfile
from engine.deviation_flagging import (
DeviationFlagging,
DeviationRule,
DeviationRuleRegistry,
ThresholdOperator,
)
from engine.node_runtime import OpcuaScalarDeviationPoller, ScheduledTask
rules = DeviationRuleRegistry()
rules.register(
"mes-weld-strength",
DeviationRule(field="weld_strength_n", op=ThresholdOperator.LT, threshold=8.5),
)
deviation_flagging = DeviationFlagging(rules, queue)
connector = OpcuaConnector(
OpcuaConnectorProfile(endpoint="opc.tcp://plc.line3:4840", node_id="ns=2;s=LotA.WeldStrengthN")
)
poller = OpcuaScalarDeviationPoller(
connector, deviation_flagging, data_source="mes-weld-strength", values_field="weld_strength_n"
)
task = ScheduledTask(name="weld-strength-check", interval_seconds=5.0, run=poller.poll_once)
This is a concrete instance of section 3's "scheduled check" primitive. It is built for a numeric telemetry point with no push subscription of its own, driving a threshold check (Deviation Flagging's weld-strength SPC check). It is the glue between OpcuaConnector.poll() and DeviationFlagging.check_batch, the same role MesIngestionProducer plays for the ingestion path.
Two distinct field names
poll_value_key(default"value") isOpcuaConnector.poll()'s fixed result-dict key. It is the sidecar RPC's"read"response shape, not a Node Type author's choice.values_fieldis theDataPoint.valueskey the resulting point carries. It must match whateverDeviationRule.fieldthe caller registered.
Deduplication
A repeated identical poll is deduped the same way MesIngestionProducer's data_change dedup guard does it. A poll cadence shorter than how often the underlying reading changes must not enqueue a fresh "deviation" row (and re-draft a disposition) on every poll of a value that hasn't moved.
A genuinely new reading always gets its own fresh uuid4() id and its own Trigger. It is deliberately not a value-derived deterministic id, since a real physical reading recurring at the same value at a later, unrelated time is still a fresh observation, not a redelivery of the earlier one.
The very first poll
An instance's very first poll is a third case, not just "changed" or "unchanged". By default it silently seeds the dedup baseline and returns, never reaching check_batch (or build_point, for OpcuaDerivedDeviationPoller below) at all. This is the same first-time suppression MesIngestionProducer._on_event applies to a subscription's initial-value announcement (section 4), applied to a poll cadence instead.
The reason: an OPC UA node has no "current state" distinct from whatever value it happens to hold the moment this poller's connector first reads it. A freshly reset target (a simulator's unset-value default, for example WeldStrengthN=0.0) would otherwise look exactly like a genuine reading on that first poll. That would be a spurious deviation on every MES startup, before any real event.
evaluate_first_poll=True opts a caller out of that suppression, so the first poll is evaluated exactly like every later one. It is a constructor keyword on both classes, plumbed from DeviationPollTarget.evaluate_first_poll (engine/deviation_flagging_config.py).
- It is correct for a real PLC/SCADA. The value already sitting there is a genuine physical reading, not a reset artifact, and a Node restart shouldn't blind a quality check to an already in-progress real deviation.
- It is safe for a simulated target once its own idle default is itself in-spec.
- The weld-strength SPC check (
engine/node_main.py) is wired this way, so the target's idleWeldStrengthNvalue must be in-spec (for example9.5, not0.0). Verifying that is the caller's job, not this class's. Passingevaluate_first_poll=Trueagainst a target whose idle default is genuinely out-of-spec reintroduces the exact spurious-deviation-on-startup failure this suppression exists to prevent.
6. A poller whose point needs deriving, not just renaming: OpcuaDerivedDeviationPoller
from engine.node_runtime import OpcuaDerivedDeviationPoller, ScheduledTask
from engine.exceptions import KindredError
def build_point(actual_hours_per_unit):
return build_variance_data_point( # engine/costing_variance.py - a live ERP query
peer_client,
data_point_id=uuid.uuid4(),
order_id="ORD-1001",
milestone_type="final",
actual_cost=actual_hours_per_unit * 42.0,
data_source="costing_milestone_variance",
node_instance_id=node_instance_id,
)
poller = OpcuaDerivedDeviationPoller(
connector,
deviation_flagging,
build_point=build_point,
exceptions=(KindredError,),
context="costing-variance-poller:costing_milestone_variance",
)
task = ScheduledTask(
name="costing-variance:costing_milestone_variance", interval_seconds=5.0, run=poller.poll_once
)
This has the same poll-cadence and dedup shape as section 5's OpcuaScalarDeviationPoller. It is for a check whose DataPoint can't be built from the raw reading alone: Costing Milestone variance needs a live ERP standard-cost figure layered on top of the raw actual-cycle-time reading first.
build_pointis that layering step, supplied by the caller (engine/node_main.py). The class itself stays Node-Type and use-case agnostic. Nothing inengine/node_runtime.pyimportsengine.communication_interfaceorengine.costing_varianceto make this work.exceptions=names whatbuild_pointcan raise as a recoverable, log-and-retry-next-tick failure (for exampleengine.exceptions.KindredError, covering an unreachable ERP peer or a non-positive standard cost). It follows thepoll_or_logcontract every other poll-cadence caller in this module follows, applied to the point-builder step rather than just the raw connector poll. An exception not named inexceptions=still propagates uncaught, as any other genuine bug does.- Dedup runs before
build_point. The dedup guard runs beforebuild_pointis ever called, not after. An unchanged reading must not spend a second live peer query re-deriving the sameDataPointit already derived, not just avoid re-enqueueing a duplicate Trigger.
Pitfalls
The dispatch loop and scheduled tasks
- A genuine bug in a handler's
steppropagates uncaught, the same asdispatch_claimed_entryitself (see the Pitfalls intrigger-dispatch-queue.md). This kills the wholerun_trigger_dispatch_loopthread, leaving that one rowclaimed. A process supervisor restarting the node process is what resolves it: the nextrun_trigger_dispatch_loopcall reclaims the row throughreclaim_orphaned_claims()at its startup. A deterministically buggystepwill crash the loop again on that same row. That is a real bug needing a code fix, not something retried away. reclaim_orphaned_claims()assumes a single consumer per node instance. It unconditionally resets everyclaimedrow, with noclaimed_atage check. That is safe only because exactly onerun_trigger_dispatch_loopis ever meant to run against one node instance's queue at a time. A second, concurrently running loop against the same table would have its own in-flight claims reset out from under it.ScheduledTask.runexceptions are not caught by its own background thread.- Unlike a claimed row's
step(wrapped in Try/Catch throughdispatch_claimed_entry), a scheduled task'srunis called directly. The same "any other exception is a genuine bug" stance applies, but there is no retry or dead-letter wrapping around it. - Since each
ScheduledTaskruns on its own thread, an uncaught exception there kills only that one task's own cadence. From the loop's perspective that is silent: Python's defaultthreading.excepthookprints it to stderr, nothing more. The rest of the dispatch loop and every other scheduled task keep running unaffected. - A scheduled task that itself needs Try/Catch semantics (for example a polling producer whose connector can be transiently unreachable) should wrap its own
runaccordingly.run_fault_tolerant_ingestioninengine/conformance.pyis the existing fetch-plus-ingest-under-Try/Catch shape for exactly that case. Don't rely on thread isolation alone to keep a real, recurring failure from going unnoticed.
- Unlike a claimed row's
The pollers
OpcuaScalarDeviationPoller.poll_oncefails silently on a wrongnode_idor field mismatch. Apoll_value_keythat doesn't exist inOpcuaConnector.poll()'s result (a misconfigurednode_idreading the wrong kind of node), or a non-numeric value, both just skip that poll with no error and no Trigger enqueued. This is the same "not every gap is a failure" stanceDeviationFlagging.check_batchtakes for a point missing its rule's field. A genuinely misconfigureddeviation_flaggingfragment therefore degrades to silent do-nothing, not a startup-time or first-poll error. It is worth a periodic sanity check against a known-good reading during commissioning. This module does not surface it on its own.- A transient
SidecarErrorduringpoll_onceis caught and logged (logger.warning), not raised.run_trigger_dispatch_loopcallsScheduledTask.runwith no Try/Catch wrapping of its own (see the pitfall above). An uncaughtpoll()failure would permanently kill this poller's scheduled-task thread on the very first transient hiccup, silently ending the SPC check's cadence for the rest of the process's life. The main dispatch loop and every other scheduled task are unaffected either way, since each runs on its own thread, but losing this one check's cadence to a single transient failure would still be a real, silent gap. The next scheduled tick tries again instead. This method has no Activity-Log-backed retry budget of its own to exhaust the way a claimed row'sstepdoes. - The dedup baseline (
_last_value) is only ever updated once a poll's value is confirmed numeric. A single bad or non-numeric reading between two identical valid ones is skipped without touching_last_value. It must not corrupt the baseline a later, still-identical valid reading needs to dedup correctly against. Otherwise the same ongoing excursion would spuriously re-fire a second Trigger the moment a transient bad reading interrupts an otherwise unchanged value. - A poll cadence coarser than the underlying reading's real-world reset window can miss a transient excursion entirely.
poll_onceonly ever sees whatever value is current at the moment it polls, never a history of readings between polls (unlike a client-serverdata_changesubscription, which observes every transition).poll_interval_secondsis a per-Node-instance config value precisely so an operator can tune it against how fast the monitored process actually changes. - A same-value poll is skipped, and logged at DEBUG.
OpcuaDerivedDeviationPoller.poll_once(andOpcuaScalarDeviationPollerandOpcuaMaterialConsumptionPoller, which delegate to it or share its shape) does not re-fire a check on an unchanged reading.- The skip logs at DEBUG ("same-value poll skipped (value=...) - poller is running, reading just hasn't changed since the last tick").
OpcuaMaterialConsumptionPollerlogs the same withmaterial_id. A same-value skip can therefore be told from a poller that never started, an unreachable sidecar or a wrong config. - Re-sending an identical value therefore produces no
trigger_queuerow and noactivity_logentry, because the poller's in-memory_last_valuealready holds it. Restarting the database or a driver process does not clear a running node's in-memory baseline.
- A test or driver script that calls
poll_onceorScheduledTask.runexactly once and expects an immediate fire must seed the baseline first, unless its poller was built withevaluate_first_poll=True.- With the default
False, an instance's very first poll never reachescheck_batchat all (see "The very first poll" in section 5). Callpoll_onceonce to seed, then poll again for the reading a test actually wants evaluated. - A Node instance's own
run_trigger_dispatch_loopdoes this correctly with no caller action._run_scheduled_task_looprunstask.run()once immediately and then everyinterval_seconds, so the immediate call becomes the seed and the next scheduled tick is real. The gap only bites a hand-driven test that never lets that natural second call happen. - A poller built with
evaluate_first_poll=Truehas no such gap: its firstpoll_onceevaluates immediately, with no seed call needed in a test or in the field.
- With the default
The MES ingestion producer
MesIngestionProducer._on_event's first-event suppression survives a mid-session OPC UA reconnect.- The suppression's accepted tradeoff is that a MES process that restarts mid-shift won't pick up a real in-flight order, and Reconciliation recovers state after a restart. That is deliberate for an actual restart, where
self._last_data_change_valueis empty because the whole object was rebuilt. - A reconnect must not re-arm it.
OpcuaConnector's self-healing resubscribe reissues a freshmonitored_item_idfor every item, so a dedup baseline keyed bymonitored_item_idwould seefirst_timetrue again for every affected item and silently absorb the next event. - The baseline is therefore keyed by
node_id, which never changes across a resubscribe.self._item_node_idmaps each reissuedmonitored_item_idback to itsnode_id, populated byrun(). run()logs an INFO line when it subscribes anode_idit already holds ("monitored_item_id reissued as ... this is a mid-session OPC UA reconnect, not a process restart; dedup baseline for this node_id is preserved").- A genuine process restart still starts with an empty baseline, as designed.
- The suppression's accepted tradeoff is that a MES process that restarts mid-shift won't pick up a real in-flight order, and Reconciliation recovers state after a restart. That is deliberate for an actual restart, where
MesIngestionProducer.run()retries its own initial subscribe attempt, bounded.deviation_flagging,costing_varianceandmaterial_consumptionall run throughpoll_or_log, which catches any exception and retries on the next tick, unbounded. Butrun()is called directly innode_main.py'smain()(runtime.producer.run()), with nothing between it and an uncaught exception killing the whole process.- The ingestion producer is the one connector whose failure means this Node instance can't ingest anything, not just lose one data source. A target OPC UA server still settling from its own restart can reject the very first subscribe attempt with
SidecarError: BadConnectionRejected. - So
run()retries its subscribe attempt up toINGESTION_STARTUP_RETRY_ATTEMPTStimes (INGESTION_STARTUP_RETRY_DELAY_SECONDSapart) onSidecarError. It re-runs the whole attempt from the top each time rather than tracking which node_id failed. That is safe, since a node_id already subscribed from an earlier partial attempt just logs as a resubscribe (section 4's behavior). - It is deliberately bounded, not unbounded like the pollers. A genuinely broken config (wrong endpoint, wrong node_id) still surfaces as a clear failure within a bounded window (5 attempts, about 12 s by default), rather than hanging forever against a target that will never come up. This is the same blind-retry-then-give-up tradeoff
poll_or_logaccepts. It does not try to distinguish "target unreachable" from "bad config"SidecarErrorsubtypes first.
Release: v0.11.0